Ingro EnergySims

DESIGNED IN INDIA · FOR SOLAR EPCs & INSTALLERS

How much solar
How much storage
What it saves

Ingro SIMS turns a customer’s bills into a costed, defensible solar + storage recommendation — in minutes, under your name.

WHAT YOU PROVIDE

  • 12 months of bills
  • Site location & area
  • Existing solar, if any
SIMS DETERMINES THE OPTIMAL SIZE
RECOMMENDED OPTIMAL CONFIGURATIONSAMPLE FIGURES

2.4 MWp solar + 1.8 MWh battery

SAVES

0.0 Cr / yr

BILL TODAY → AFTER

0.00.0 Cr

BATTERY PAYBACK

0.0 yrs

Feasibility reportFinancial modelComparison sheet

Trusted by

Apar Industries
Apar Industries
JSW Energy
JSW Energy
Delhi Metro
Delhi Metro
JSPL
JSPL
Skipper Industries
Skipper Industries
Prakash Industries
Prakash Industries
Spark Minda
Spark Minda
Bhageria Group
Bhageria Group
Taj Group
Taj Group
Apar Industries
Apar Industries
JSW Energy
JSW Energy
Delhi Metro
Delhi Metro
JSPL
JSPL
Skipper Industries
Skipper Industries
Prakash Industries
Prakash Industries
Spark Minda
Spark Minda
Bhageria Group
Bhageria Group
Taj Group
Taj Group
UPDATE

Effective 1 April 2026, Maharashtra requires energy storage with solar installations above 100 kW — 50% of solar capacity, for two hours. Further states are expected to follow.

HOW IT WORKS

From twelve bills to a signed proposal.

SIMS follows the same path an engineer would — it just walks it in minutes, and never skips the arithmetic.

  1. 1

    Create a project

    One project per site or consumer. Bills, tariff choices, assumptions and every analysis run are saved to it as you go.

  2. 2

    Feed it the bills

    Twelve months of bills, or interval meter data where available. The consumption pattern, the DISCOM and the tariff category are read from them.

  3. 3

    Point at the site

    Location and available roof or land area. SIMS derives the generation profile from NASA satellite irradiance — existing solar sharpens it further.

  4. 4

    Confirm the tariff

    The DISCOM’s time-of-day zones, seasonal rates and demand charges come from the built-in library — current with every revision.

  5. 5

    Read the recommendation

    Every solar × battery combination is simulated against the customer’s year; the build with the fastest return rises to the top.

EPCs & installers

A proposal prepared in the first meeting, issued under your brand.

Energy consultants

Any quotation re-priced on the customer’s own data, before it is accepted.

C&I consumers

The rooftop case checked independently before signing anything.

EVERY STUDY RESTS ON THE SAME THREE INPUTS

The bills

Monthly totals or interval data — the load profile, DISCOM and category come straight from them.

The site

Location and usable area; satellite irradiance fills in everything else.

Existing generation

Where solar is already installed, its output sizes storage against reality.

INSIDE THE SIMULATOR

Three ways to simulate. One search for the best.

Every mode runs the customer's actual year hour by hour — dispatch, efficiency, depth-of-discharge and all. They differ only in what they optimise.

The baseline

Solar only

Sizes PV for maximum self-consumption with minimal wastage — the headline savings before storage enters the picture.

  • Self-consumption limit
  • Wasted-solar warning
The full case

Solar + BESS

Sizes solar and storage jointly against time-of-day zones — charging on midday surplus, discharging into the evening peak.

  • ToD arbitrage
  • Peak shifting
  • Efficiency losses modelled
For demand-heavy bills

BESS peak-shaving

Sizes a battery that flattens demand peaks — standalone, or alongside solar already on the roof.

  • Demand charges
  • Retrofit-friendly

THE SEARCH BEHIND THE RECOMMENDATION

SAMPLE SWEEP · ILLUSTRATIVE VALUES
00.61.21.82.43.03.6
08.96.45.14.64.95.87.4
0.68.15.64.43.94.25.06.6
1.27.65.14.03.43.74.56.1
1.87.34.93.73.23.54.45.9
2.47.45.03.93.43.84.76.3
3.07.85.44.23.84.25.16.8
SOLAR CAPACITY, MWp →  ·  ↑ BATTERY, MWh
Each square is a complete simulation — one proposed build, run across the customer’s whole year. SIMS sweeps hundreds of these combinations and hands you the fastest-returning size 2.4 MWp + 1.8 MWh (ringed, 3.2 yrs) — the same configuration quoted throughout this page.

Ranked by your objective:

  • Lowest bills
  • Least grid use
  • No solar wasted
  • Most solar used
Switching the objective re-ranks every option instantly — no re-run.

DESIGNED IN INDIA, NOT ADAPTED TO IT

It knows what your DISCOM actually does.

Global sizing tools require Indian tariffs to be built by hand. Ingro SIMS is designed around India’s regulatory structure — DISCOM by DISCOM — and maintained as it changes.

DelhiRajasthanGujaratKarnatakaTamil NaduMaharashtrastorage mandate · Apr 2026
Tariff structures encoded state by state — markers show the leading C&I solar markets.

ONE DAY UNDER A TIME-OF-DAY TARIFF

MSEDCL-STYLE ZONES · ILLUSTRATIVE RATES
₹6.1
₹7.4
₹9.1
₹7.4
₹9.3
₹6.1
00:0006:0009:0012:0018:0022:0024:00
Peak-hour power costs 25–40% more than daytime power. Storage earns its return by shifting low-cost solar hours into high-cost evening ones — within windows that differ by state and DISCOM. SIMS carries each one.

REGULATION MOVES. SIMS IS MAINTAINED WITH IT.

  1. Apr 2024

    Time-of-day tariffs become universal for C&I consumers across India.

  2. Every year

    DISCOM tariff orders revise rates, zone boundaries and charges.

  3. Apr 2026

    Maharashtra mandates storage with solar projects above 100 kW.

  4. Next

    Further states are expected to follow. Each change is encoded as it takes effect.

Your DISCOM is built in

Time-of-day zones, seasonal rates and demand charges for DISCOMs across India — MSEDCL to BESCOM. SIMS identifies the DISCOM from the customer’s bill and applies its rules; nothing is rebuilt by hand.

Current with every revision

Tariff orders, ToD revisions and storage mandates are encoded as they take effect — so a study priced today reflects the rules in force today.

Numbers that withstand review

Savings are computed the way the bill is charged — slab by slab, season by season — and every assumption is carried into the workbook, where it stands up to independent scrutiny.

WHAT YOU GET

What a study delivers.

Everything below is generated from the study — sized, costed and branded for the customer.

sims.ingroenergy.com/sizing-studioSAMPLE DATA

Today

grid only

₹3.9 Cr / yr bill

Saves
Battery payback

Solar only

2.4 MWp

₹3.1 Cr / yr bill

Saves
₹80 L / yr
Battery payback

Solar + battery

2.4 MWp + 1.8 MWh

RECOMMENDED

₹2.8 Cr / yr bill

Saves
₹1.1 Cr / yr
Battery payback
3.2 yrs

Sized to the objective

Select the customer’s objective and the recommended configuration follows it — the ranking always serves the goal, not a single metric.

The complete financial case

Capital cost, annual savings, payback and lifetime return — in rupees, computed against the customer’s actual bill. Ownership and PPA structures, both.

Today vs Solar vs Solar + Battery

A single side-by-side comparison of the current bill, solar, and solar with storage — the summary a decision is made on.

A report issued under your brand

A branded feasibility report for the customer, and a working financial model their finance team can verify line by line.

Results in minutes — a proposal in the first meeting, not the following week.

BENCHMARK ANYTHING

Benchmark any quotation.

Enter any proposed configuration — a competitor's quotation or the customer's own estimate. SIMS evaluates it on the same consumption data and the same tariff, alongside the recommended build. The comparison speaks for itself.

ANNUAL SAVINGS, COMPARED

SAMPLE FIGURES
SIMS recommended · 2.4 MWp + 1.8 MWh₹1.1 Cr
Quoted elsewhere · 3.0 MWp + 1.0 MWh₹96 L
A ₹14 lakh annual difference, established on the customer’s own data.
Designed in India, for Indian regulationThe customer’s own consumption dataNASA satellite irradiancePublished DISCOM tariffsEvery figure traceable in the workbook

Evaluate it on a live project.

A consultant-grade feasibility study, produced in minutes. Launch offer: 5 projects included for the first 1,000 accounts.